Pneumatic Circuit

Semester 5

Task

Pneumatic door control of a bus

The passenger door of a bus (for example a KSRTC bus or an airport bus) is opened and closed using compressed air. The driver operates a lever switch from the driver's seat, and the door opens and closes.

Using the components given, set up the pneumatic circuit for this door system (do both: with a single acting cylinder and with a double acting cylinder) and operate the door to open and close.

⚠ Do not operate the trainer from this page alone – always work under the guidance of an instructor or an experienced person. We are not responsible for any loss, damage or injury that results from using this information.

Safety

Safety first

  1. Check that every tube is pushed fully into its fitting and that no tube is cut or damaged.
  2. Close the sliding valve before you connect or pull out a tube.
  3. Keep your face and ears away from tube ends and open ports while the air is on.

If a tube comes off

If a tube comes off, or a valve is opened by mistake, switching OFF the compressor does not stop the air – the tank still holds the pressure. Close the right valve (the sliding valve) to stop the air.

Compressed air can injure

If a tube bursts or comes loose, compressed air blown into an eye or an ear can cause serious injury. Always work with safety in mind.

Circuit Diagram – Draw & Simulate

Before building the circuit on the trainer, draw it with the standard symbols and check that it works.

3D Model

How to use

  1. Choose Single acting or Double acting at the top of the lab.
  2. Pick a 10 mm or 4 mm tube from the bar below the model. Use the Plug to close a 4 mm port that is not used.
  3. Tap the first port, then the second port, to connect the tube.
  4. Switch the power ON at the mains switch (or the ⏻ Power button at the top of the lab).
  5. Open the sliding valve and move the 5/2 lever to operate the cylinder.
  6. Tap any part to see its name. Tap Parts to show the part letters.

Drag to rotate · Pinch or scroll to zoom · ⌂ returns to the full view · Use Full screen for more space

Comments

    Loading comments…

    Please keep it friendly: no bad words or links.

    Engineering Drawing

    Pneumatic circuit diagrams of the bus door: with a single acting cylinder (left) and with a double acting cylinder (right). Each has the compressor, FRL unit, sliding valve and 5/2 hand lever valve

    Resources